Orion-system PT-Link II BACnet2 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Orion-system PT-Link II BACnet2. Orion System PT-Link II BACnet2 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
PT-Link II BACnet2
®
Technical Guide
www.orioncontrols.com
RNE Controller Code: SS1045
VCB-X Controller Code: SS1051 Version 2.0
VCM-X Controller Code: SS1026 & Y200920 Version 2.0 and up;
VCM-X Modular Controller Code: SS1030 & SS1034
VCM-X WSHP Controller Code: SS1032 & SS1033
SA Controller Code: Y200921
VCM Controller Code: SS1016, Y200409, Y200616, Y200822
www.orioncontrols.com
WattMaster Label
#LB102082
Rev. 01A
OE368-23B-BACNET2
PT-LINK II PROTOCOL
TRANSLATOR
FOR BACNET
+24 VAC
GND
LOOP
LED 1
LED 2
= RAPID BLINK
= BLINKS QTY
CONTROLLERS
= STEADY BLINK
PROTO
TIMER
WATCH DOG
H-BEAT
= RAPID BLINK
= STEADY BLINK
= ON SOLID
= STEADY BLINK
LED BLINK CODES (NORMAL)
Przeglądanie stron 0
1 2 3 4 5 6 ... 59 60

Podsumowanie treści

Strona 1 - Technical Guide

PT-Link II BACnet2®Technical Guidewww.orioncontrols.comRNE Controller Code: SS1045 VCB-X Controller Code: SS1051 Version 2.0VCM-X Controller Code:

Strona 2 - Table of Contents

PT-Link II BACnet® Technical Guide PT-Link II Interface10Connecting To The PT-Link IINOTE: The preferred method of confi guration i

Strona 3 - General Information

PT-Link II Interface PT-Link II BACnet® Technical Guide 11Figure 13: RUINET PT-Link Selection Menu7.) On subsequent connections, a list of

Strona 4 - Setting Up Your PT-Link II

PT-Link II BACnet® Technical Guide PT-Link II Interface12Changing the Confi g.csv File14.) The last change you may need to make is the

Strona 5

PT-Link II Interface PT-Link II BACnet® Technical Guide 1317.) At the next screen, (Figure 22), type <D> again.15.) Once the change

Strona 6

PT-Link II BACnet® Technical Guide PT-Link II Interface14Troubleshooting the PT-Link Controller Addressing WattMaster Devices in a BAC

Strona 7 - IP Address Confi guration

PT-Link II Interface PT-Link II BACnet® Technical Guide 15PT-Link II Board LEDsThe PT-Link II BACnet® is equipped with LEDs that can be used

Strona 8

PT-Link II BACnet® Technical Guide PT-Link II Interface16Troubleshooting the PT-Link II Controller - OE368-23B-BACnetFigure 25: PT-Li

Strona 9

PT-Link II Interface PT-Link II BACnet® Technical Guide 17Troubleshooting the PT-Link II Controller - OE368-23-BACnetFigure 27: PT-Link II B

Strona 10 - Running RUINET

PT-Link II BACnet® Technical Guide PT-Link II Interface18Troubleshooting the PT-Link II ControllerFigure 29: Data Array Overview Scre

Strona 11 - Changing the Confi g.csv File

PT-Link II Interface PT-Link II BACnet® Technical Guide 19Programming the PT-Link II with BootLoaderThe PT-Link II is equipped with the abili

Strona 12

Table of ContentsWattMaster Controls, Inc.8500 NW River Park Drive · Parkville, MO 64152Toll Free Phone: 866-918-1100PH: (816) 505-1100 · FAX: (816)

Strona 13 - Technical Guide

PT-Link II BACnet® Technical Guide PT-Link II Interface20Updating the PT-Link II Controller13.) The Application ID should be SS1035

Strona 14 - Examples:

PT-Link II Interface PT-Link II BACnet® Technical Guide 21Updating the PT-Link II ControllerRevised 10/11/12Finding What COM Port Number th

Strona 15 - PT-Link II Board LEDs

PT-Link II BACnet® Technical Guide PT-Link II Interface22Updating the PT-Link II ControllerRevised 10/11/124. To assign a port number

Strona 16 - ProtoCessor Module LEDs

PT-Link II Interface PT-Link II BACnet® Technical Guide 23VCB-X & VCM-X Modular Data ArraysTable 4: VCM-X Modular Data Array For Field S

Strona 17

PT-Link II BACnet® Technical Guide PT-Link II Interface24VCM-X WSHP Tulsa / RNE Data ArrayRevised 4/2/13Table 5: VCM-X WSHP (Tulsa) /

Strona 18

PT-Link II Interface PT-Link II BACnet® Technical Guide 25Table 6: VCM-X WSHP (Coil) Data Array For Field ServerVCM-X WSHP (Coil) Data Array

Strona 19 - Revised 3/15/11

PT-Link II BACnet® Technical Guide PT-Link II Interface26VCM Data Array For Field ServerOffset 012345670AppVer ClSt HtSt OaWtbl TpDmnd

Strona 20

PT-Link II Interface PT-Link II BACnet® Technical Guide 27Appendix AUse the standard EIA/TIA color code for "CROSS OVER CABLE" as s

Strona 21 - <Hardware> tab

PT-Link II BACnet® Technical Guide PT-Link II Interface28Appendix BProtoCessor Driver - (PICS) BACnet Protocol Implementation Conforma

Strona 22

PT-Link II Interface PT-Link II BACnet® Technical Guide 29Appendix BSegmentation Capability: NoneStandard Object Types Supported  Device Obj

Strona 23 - 0 1 234567

PT-Link II Interface 3 PT-Link II BACnet® Technical GuideThe OE368-23B-BACNET2, PT-Link II BACnet® provides bi-direction-al communication between y

Strona 24

PT-Link II BACnet® Technical Guide PT-Link II Interface30Appendix C - Node ID (Device Instance) & MAC AddressBank A DIP Switch Set

Strona 25

PT-Link II Interface PT-Link II BACnet® Technical Guide 31Appendix C - Node ID (Device Instance) & MAC AddressBank A DIP Switch Settings

Strona 26

PT-Link II BACnet® Technical Guide PT-Link II Interface32Appendix C - Node ID (Device Instance) & MAC AddressBank A DIP Switch Set

Strona 27 - Appendix A

PT-Link II Interface PT-Link II BACnet® Technical Guide 33Appendix D - VCB-X BACnet ParametersBACnet Properties for the VCB-X Controller Para

Strona 28 - Appendix B

PT-Link II BACnet® Technical Guide PT-Link II Interface34Appendix D - VCB-X BACnet ParametersBACnet Properties for the VCB-X Controlle

Strona 29

PT-Link II Interface PT-Link II BACnet® Technical Guide 35Appendix D - VCB-X BACnet ParametersBACnet Properties for the VCB-X Controller Para

Strona 30

PT-Link II BACnet® Technical Guide PT-Link II Interface36Appendix D - VCB-X BACnet ParametersRevised 1/20/12BACnet Properties for the

Strona 31

PT-Link II Interface PT-Link II BACnet® Technical Guide 37Appendix D - VCB-X BACnet ParametersBACnet Properties for the VCB-X Controller Para

Strona 32

PT-Link II BACnet® Technical Guide PT-Link II Interface38Appendix D - VCB-X BACnet ParametersBACnet Properties for the VCB-X Controlle

Strona 33

PT-Link II Interface PT-Link II BACnet® Technical Guide 39VCB-X PT-Link II BACnet® Property Identifi er:The PT-Link II BACnet® Link amends the

Strona 34

PT-Link II BACnet® Technical Guide PT-Link II Interface4Setting Up Your PT-Link IIFigure 1: PT-Link II BACnet® Dimensions and Compone

Strona 35

PT-Link II BACnet® Technical Guide PT-Link II Interface40Appendix E - VCM-X Modular & WSHP & RNE BACnet ParametersBACnet Prope

Strona 36

PT-Link II Interface PT-Link II BACnet® Technical Guide 41Appendix E - VCM-X Modular and WSHP BACnet ParametersBACnet Properties for VCM-X WS

Strona 37

PT-Link II BACnet® Technical Guide PT-Link II Interface42Appendix F - VCM-X BACnet ParametersBACnet Properties for the VCM-X Controlle

Strona 38

PT-Link II Interface PT-Link II BACnet® Technical Guide 43Appendix F - VCM-X BACnet ParametersBACnet Properties for the VCM-X Controller Para

Strona 39 - BACNETPropertyIdentifi er :

PT-Link II BACnet® Technical Guide PT-Link II Interface44Appendix F - VCM-X BACnet ParametersBACnet Properties for the VCM-X Controlle

Strona 40

PT-Link II Interface PT-Link II BACnet® Technical Guide 45Appendix F - VCM-X BACnet ParametersBACnet Properties for the VCM-X ControllerParam

Strona 41

PT-Link II BACnet® Technical Guide PT-Link II Interface46Appendix F - VCM-X BACnet ParametersBACnet Properties for the VCM-X Controlle

Strona 42

PT-Link II Interface PT-Link II BACnet® Technical Guide 47Appendix F - VCM-X BACnet ParametersVcmxAlarmGroup1Bits ::= BIT STRING {SupplyTempS

Strona 43

PT-Link II BACnet® Technical Guide PT-Link II Interface48Appendix G - SA Controller BACnet ParametersBACnet Properties for SA Controll

Strona 44

PT-Link II Interface PT-Link II BACnet® Technical Guide 49Appendix G - SA Controller BACnet ParametersBACnet Properties for SA Controller Par

Strona 45 - Cooling

PT-Link II Interface PT-Link II BACnet® Technical Guide 5Connection and Wiring InformationFigure 2: PT-Link II BACnet® Interface WiringModul

Strona 46

PT-Link II BACnet® Technical Guide PT-Link II Interface50Appendix G - SA Controller BACnet ParametersBACnet Properties for SA Controll

Strona 47

PT-Link II Interface PT-Link II BACnet® Technical Guide 51Appendix G - SA Controller BACnet ParametersBACnet Properties for SA ControllerPara

Strona 48

PT-Link II BACnet® Technical Guide PT-Link II Interface52BACnet Properties for the VCM ControllerParameter Name Object Description Lim

Strona 49

PT-Link II Interface PT-Link II BACnet® Technical Guide 53Appendix H - VCM BACnet ParametersBACnet Properties for the VCM ControllerParameter

Strona 50

PT-Link II BACnet® Technical Guide PT-Link II Interface54BACnet Properties for the VCM ControllerParameter Name Object Description Lim

Strona 51

PT-Link II Interface PT-Link II BACnet® Technical Guide 55BACnet Properties for the VCM ControllerParameter Name Object Description LimitsFan

Strona 52

PT-Link II BACnet® Technical Guide PT-Link II Interface56Appendix H - VCM BACnet ParametersBACnet Properties for the VCM ControllerPar

Strona 53 - RaTpOst AV: 65 If the Return

PT-Link II Interface PT-Link II BACnet® Technical Guide 57Appendix H - VCM BACnet ParametersVcmExternal Relays1-2Bits::= BIT STRING {Expansio

Strona 54

PT-Link II BACnet® Technical Guide PT-Link II Interface58Notes

Strona 55

PT-Link II Interface PT-Link II BACnet® Technical Guide 59Notes

Strona 56

PT-Link II BACnet® Technical Guide PT-Link II Interface6PT-Link II Hardware ConnectionYou have two options for connecting the PT-Link

Strona 57

Form: OR-PTLNK2BTL-TGD-01G April 2013All rights reserved. Printed in the USA

Strona 58

PT-Link II Interface PT-Link II BACnet® Technical Guide 74.) As shown in Figure 6, click <Properties> in the lower left of the window.

Strona 59

PT-Link II BACnet® Technical Guide PT-Link II Interface8Figure 8: Internet Protocol Properties Window6). Select the radio button in

Strona 60

PT-Link II Interface PT-Link II BACnet® Technical Guide 9Confi guring the PT-Link DIP SwitchesPT-Link DIP Switch Confi gurationIf the BACnet ad

Komentarze do niniejszej Instrukcji

Brak uwag