Orion-system VCM Component Instrukcja Użytkownika Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 96
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
Component & System Wiring 17
EPROM
U3
U5
RAM
CX2
1
U2
R
1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILI
PS
D1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D
4
G
ND
24VAC
TB1
D5
C11
U12
LED 2
POWER
V1
R25
R26
C7
CX15
C
X13
PROC.
DRIVER
LOOP
DRIVER
LOCAL LOOP
G
ND
AIN
2
AIN
1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN1
0-10V
4-20mA
THERM
TB3
U15
LD5
LD6
U
13
C8
LED 1
RV1
R4
VREF
CX2
U11
YS101900PMINILINK
POLLING
DEVICE
REV.1
OFF
1
2
4
8
16
32
C
X14
NETWORK
DRIVER
RN3
SHLD
SHLD
T
T
TB4
R
R
U
14
NETWORK
LOOP
P5
AD
D
P3
R
24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
C
X6
C
X1
U7
U1
X1
C3
C
1
R
3
CX7
EPROM
U3
U5
RAM
C
X2
1
U2
R
1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILIPS
D
1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D
4
G
ND
24VAC
TB1
D5
C11
U12
LED 2
POWER
V1
R25
R26
C7
C
X15
C
X13
PROC.
DRIVER
LOOP
DRIVER
LOCAL LOOP
G
ND
AIN
2
AIN
1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN1
0-10V
4-20mA
THERM
TB3
U15
LD5
LD6
U
13
C8
LED 1
RV1
R4
VREF
CX2
U11
YS101900PMINILINK
POLLING
DEVICE
REV.1
OFF
1
2
4
8
16
32
CX14
NETWORK
DRIVER
RN3
SHLD
SHLD
T
T
TB4
R
R
U
14
NETWORK
LOOP
P5
ADD
P3
R
24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
C
X6
CX1
U7
U1
X1
C
3
C
1
R3
CX7
Network
Network
Local
Local
24 VAC
(6 VA)
24 VAC
(6 VA)
Back View of CommLink
Front View of CommLink
CLII
omm ink
LOOP
24V
T
G
R
GND
REMOTE LINK
(DTE)
COMPUTER
(DCE)
485 LOOP
STATUS
POW
ER
COMP
RLINK
SERIAL #
CONTROLS
110 VAC To
24 VAC
Power Pack
CommLink
MiniLink PD Loop 1
MiniLink PD Loop 2
Note: See Page 2 Of
This Drawing For
Optional Computer
And Remote Link
Connection Diagram.
Note: Set CommLink
Internal Switch To “Multi”
Line Voltage
24 VAC
(8 VA)
VAV/Zone
Controller
HVAC Unit Controller
(1 MEG)
1
0
P
HILIPS
Modular Service Tool
Mode
Selection
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
STATUS
SETPOINTS
SCHEDULES
CONFIGURATION
ALARMS
ON
OVERRIDES
BALANCE - TEST
Connect To Next
VAV/Zone Controller
On Branch Circuit
SHLD
T
R
Typical Terminal Blocks. All
Wiring To Be T To T, SHLD (G)
To SHLD (G)&RToR
T
G
R
485 LOOP
FILENAME
DATE:
B. Crews
DESCRIPTION:
PAGE
DRAWN BY:
JOB NAME
1of3
Typical Multiple Loop Networked System
Power/Comm
Board
Line Voltage
24VAC-Size
Transformer
For Required VA Load
TB1
Connect To Modular
I/O Connectors
Located On Back
Of The System Manager
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
STATUS
SETPOINTS
SCHEDULES
ALARMS
OVERRIDES
Modular System Manager
Note: A Modular System
Manager, A Modular Service
Tool Or A PC With Prism
Software Installed Can Be
Used To Program And
Configure The Orion System.
TB2
VAC
F1
25
4A
24
S
HLD
T
R
PO
W
ER
LD1
TB1
C1
PO
W
ER
&
C
OM
M
DIST.B
OAR
D
YS101856
R
EV.0
P5
P4
P3
P1
D1
V1
R
1
P2
COMMP IN
POWER & COMM
OUT
Connect To
Other VAV/Zone
Controllers
On Loop
Connect To
Other VAV/Zone
Controllers
On Loop
Connect To
Other VAV/Zone
Controllers
On Loop
Power/Comm
Board
VAV/Zone
Controller
Line Voltage
24VAC-Size
Transformer
For Required VA Load
Note: A Maximum Of 6 VAV/Zone Controllers
Can Be Connected To Each Branch Circuit. A total
Of 16 Controllers Are Allowed Per Power/Comm
Board. Use Additional Power/Comm Boards For
Systems That Exceed 16 Controllers. See The
VAV/Zone Controller Wiring Diagram For
Power/Comm Board Transformer Sizing And
Circuit Design Information.
1
0
PHILIPS
TB2
VAC
F1
25
4A
24
SH
LD
T
R
PO
W
ER
LD
1
TB1
C1
PO
W
E
R
&
CO
M
M
DIST.BO
AR
D
YS
101856
RE
V
.0
P5
P4
P
3
P1
D1
V1
R
1
P
2
COMMP IN
POWER & COMM
OUT
Connect To Loop 2
Power/Comm
Board Or HVAC Unit
Controller
Connect To Loop
3 MiniLink PD
Wiring & Connection Diagram
O-Network-MultipleLoop1B.CDR
Networked System - Multiple Loop
10/30/03
Networked Multiple Loop System Wiring
Przeglądanie stron 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 95 96

Komentarze do niniejszej Instrukcji

Brak uwag